Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://e.ieu.edu.ua/handle/123456789/753
Назва: ETView SL versus Macintosh Direct Laryngoscope for Endotracheal Intubation Amid Simulated COVID-19 Cardiac Arrest: A Randomized Crossover Study
Інші назви: -
Автори: Chmielewski, Jaroslaw
Ключові слова: endotracheal intubation
direct laryngoscopy
ETView SL
personal protective equipment
cardiopulmonary resuscitation
COVID-19
Дата публікації: 2023
Бібліографічний опис: Evrin, T.; Dabkowski, M.; Pruc, M.; Hernik, J.; Wieczorek, W.; Chabowski, L.; Wieczorek, P.; Chmielewski, J.; Feduniw, S.; Szarpak, L. ETView SL versus Macintosh Direct Laryngoscope for Endotracheal Intubation Amid Simulated COVID-19 Cardiac Arrest: A Randomized Crossover Study. J. Clin. Med. 2023, 12, 5074. https:// doi.org/10.3390/jcm12155074
Короткий огляд (реферат): Airway management procedures, such as endotracheal intubation (ETI), pose a significant risk of aerosol generation, requiring robust personal protective equipment (PPE) against aerosolgenerating procedures (AGP). This study aimed to assess the impact of PPE-AGP on intubation success rates, time to intubation, and glottic visualization using ETView and a standard Macintosh laryngoscope (MAC). A total of 52 physicians participated in this prospective, observational, randomized crossover study conducted in a medical simulation setting. Participants included COVID-19 patients with cardiac arrest scenarios with and without PPE-AGP who were intubated with ETView and MAC. During intubation without PPE-AGP, ETView showed a similar first-pass success rate (FPS) but had a shorter intubation time and better glottal hydration compared to MAC. In scenario B (with PPE-AGP), ETView outperformed MAC in FPS, initiation time, and glottic visualization. The use of PPE-AGP had little impact on ETView’s performance. However, it negatively affected the Macintosh laryngoscope, reducing FPS and glottic visibility. Participants found intubation with ETView easier in both scenarios. In conclusion, as compared to the Macintosh laryngoscope, ETView demonstrated higher performance under the circumstances of the simulation, especially when PPE-AGP was used.
URI (Уніфікований ідентифікатор ресурсу): http://e.ieu.edu.ua/handle/123456789/753
Розташовується у зібраннях:Європейська медична школа

Файли цього матеріалу:
Файл Опис РозмірФормат 
jcm-12-05074.pdf1.57 MBAdobe PDFВідкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.