Название: | ETView SL versus Macintosh Direct Laryngoscope for Endotracheal Intubation Amid Simulated COVID-19 Cardiac Arrest: A Randomized Crossover Study |
Другие названия: | - |
Авторы: | Chmielewski, Jaroslaw |
Ключевые слова: | endotracheal intubation direct laryngoscopy ETView SL personal protective equipment cardiopulmonary resuscitation COVID-19 |
Дата публикации: | 2023 |
Библиографическое описание: | Evrin, T.; Dabkowski, M.; Pruc, M.; Hernik, J.; Wieczorek, W.; Chabowski, L.; Wieczorek, P.; Chmielewski, J.; Feduniw, S.; Szarpak, L. ETView SL versus Macintosh Direct Laryngoscope for Endotracheal Intubation Amid Simulated COVID-19 Cardiac Arrest: A Randomized Crossover Study. J. Clin. Med. 2023, 12, 5074. https:// doi.org/10.3390/jcm12155074 |
Краткий осмотр (реферат): | Airway management procedures, such as endotracheal intubation (ETI), pose a significant risk of aerosol generation, requiring robust personal protective equipment (PPE) against aerosolgenerating procedures (AGP). This study aimed to assess the impact of PPE-AGP on intubation success rates, time to intubation, and glottic visualization using ETView and a standard Macintosh laryngoscope (MAC). A total of 52 physicians participated in this prospective, observational, randomized crossover study conducted in a medical simulation setting. Participants included COVID-19 patients with cardiac arrest scenarios with and without PPE-AGP who were intubated with ETView and MAC. During intubation without PPE-AGP, ETView showed a similar first-pass success rate (FPS) but had a shorter intubation time and better glottal hydration compared to MAC. In scenario B (with PPE-AGP), ETView outperformed MAC in FPS, initiation time, and glottic visualization. The use of PPE-AGP had little impact on ETView’s performance. However, it negatively affected the Macintosh laryngoscope, reducing FPS and glottic visibility. Participants found intubation with ETView easier in both scenarios. In conclusion, as compared to the Macintosh laryngoscope, ETView demonstrated higher performance under the circumstances of the simulation, especially when PPE-AGP was used. |
URI (Унифицированный идентификатор ресурса): | http://e.ieu.edu.ua/handle/123456789/753 |
Располагается в коллекциях: | Європейська медична школа |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
jcm-12-05074.pdf | 1.57 MB | Adobe PDF | Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.